>Shut down ¾øÀÌ ¹åµ¥¸®ÀÇ »óÅ ÃøÁ¤ >¹åµ¥¸®ÀÇ ÀúÇ×°ú Àü¾Ð ¿¬¼Ó ÃøÁ¤ >Comparator ±â´É >PASS, WARNING, FAIL µîÀÇ ¾çºÎ ÆÇÁ¤ >RS-232 Interface, software ±âº»Á¦°ø
- Battery Types Tested : Secondary battery including lead storage cell,
Nickel-cadmium battery, Lithium-ion battery, nickel-metal battery and Nickel-metal hydride battery.
- Battery Capacity :0 to 500AH
- Resistance :
Ranges : 40m§Ù, 400m§Ù, 4§Ù, 40§Ù Resolution : 10µ§Ù, 100µ§Ù, 1m§Ù, 10m§Ù Accuracy : ¡¾(1%reading + 8digits) on all ranges
- Measurement : Current : 50mA, 5mA, 500µA,50µA
Frequency : 1KHz ¡¾10% Accuracy : ¡¾10%
- Voltage : Measurement : 4V, 40V
Resolution : 1mV, 10mV Accuracy : ¡¾(0.1%rdg ¡¾6digits)
- Open Circuit Voltage : ¡Â 6V
- Data Memory : Manual : 999sets, Continuous data logging : 6000 sets
- Comparator :
Setting : Resistance high and low limits and voltage throughold point Memory : 99 sets of values
- Operating Environment : 0¡É to 40¡É(32¢µ to 104¢µ), 80%RH or less, non-condensing
- Maximum Input Voltage : 50VDC
- Power Supply or AC Adapter : Six LR6 alkaline batteries
- Battery Life : 7 hours
- Dimensions / Weight : Approx. 250(L) x 100(W) x 45(H)mm
Approx. 500g including batteries
- Accessories : Instruction manual, Batteries, Test probe, RS-232 cable, Software
- Optional Accessories : AC adaptor (9V DC output)
|