óÀ½À¸·Î £ü ·Î±×ÀÎ £ü ȸ¿ø°¡ÀÔ £ü ÃֱٰԽù° £ü E-MAIL £ü Áñ°Üã±âÃß°¡
KYORITSU(ÀϺ»)
HIOKI(ÀϺ»)
FLUKE(¹Ì±¹)
Sanwa(ÀϺ»)
Å ±¤
»õÇÑ°è±â
KYORITSU(ÀϺ»)
HIOKI(ÀϺ»)
FLUKE(¹Ì±¹)
TES&PROVA(´ë¸¸)..
DADA
Å ±¤
»õÇÑ°è±â
KYORITSU(ÀϺ»)
HIOKI(ÀϺ»)
TES&PROVA(´ë¸¸)..
Kaise(ÀϺ»)
MULTI(ÀϺ»)
KYORITSU(ÀϺ»)
HIOKI(ÀϺ»)
FLUKE(¹Ì±¹)
METREL(À¯·´)
TES&PROVA(´ë¸¸)..
Sanwa(ÀϺ»)
Å ±¤
»õÇÑ°è±â
DADA
KYORITSU(ÀϺ»)
METREL(À¯·´)
KYORITSU(ÀϺ»)
HIOKI(ÀϺ»)
FLUKE(¹Ì±¹)
TES&PROVA(´ë¸¸)..
DADA
Å ±¤
»õÇÑ°è±â
TES(´ë¸¸)¼ÒÀ½°è..
SMART SENSOR ¼Ò..
CEM¼ÒÀ½°è
ÈÞ´ë¿ëÁøµ¿°è
TESTO(µ¶ÀÏ)
SMART SENSOR
TES(´ë¸¸)
CEM
¿Âµµ¼¾¼­
TOKYOPHOTO(ÀϺ»..
TES(´ë¸¸)
CEM
SMART SENSOR
ÄÚÆõβ²ÃøÁ¤±â
ÃÊÀ½Æĵβ²ÃøÁ¤±â..
Çϼ¼°¡¿Í (ÀϺ»)..
FLUKE(¹Ì±¹)
HIOKI(ÀϺ»)
DADA
Å ±¤
°Ë»ó±â(»óÅ×½ºÅ¸..
Àü±âÇü½Ä½ÂÀμ³ºñ..
½Â°­±â¾ÈÀü°ü¸®½Ã..
¼Ò¹æÇü½Ä½ÂÀοÜ1..
Á¶¸í±â±¸Çü½Ä½ÂÀÎ..
ÀÇ·á±â±âÇü½Ä½ÂÀÎ..
KYORITSU(ÀϺ»)
FLUKE(¹Ì±¹)
ȨÆäÀÌÁö°¡ »õ·Î¿î ¸ð½À ...
ȨÆäÀÌÁö ÀÌ¿ë¾à°ü
°³ÀÎÁ¤º¸º¸È£Á¤Ã¥
À̸ÞÀÏ ¹«´Ü¼öÁý °ÅºÎ °ø ...
HOME > Á¦Ç°¼Ò°³
¢º Ä«Å×°í¸® > 2. Ŭ·¥ÇÁ¸ÞŸ > KYORITSU(ÀϺ»)
±³¸®½º 2300R(0~100A.RMS)AC/DC
Á¦Ç°¸í ±³¸®½º 2300R(0~100A.RMS)AC/DC
ÆǸŰ¡¹®ÀÇ¿ä¸Á
ºê·£µåKYORITSU
¿ø»êÁöJAPAN
»ó¼¼ ¼³¸í
±¹Á¦¾ÈÀü±Ô°Ý IEC61010-1 CAT.¥²300VÁØ°Å
½Å°³¹ß ¿ÀǼ¾¼­·Î AC/DCÀÇ Àü·ùÃøÁ¤ÀÌ °¡´É
TRUE RMS ÃøÁ¤À¸·Î, ¿Ö°îµÈÆÄÇü¿¡ À§·ÂÀ» ¹ßÈÖ
Àü¾Ð°¨Áö±â´ÉÀ¸·Î È°¼±Ã¼Å©
DC Àü·ù·»Áö´Â 0Á¶Àý ±â´ÉÀ¸·Î ¿øÅÍÄ¡ 0Á¶Àý
¿ÀÅäÆÄ¿ö¿ÀÇÁ ±â´É
µ¥ÀÌÅÍ È¦µå±â´É(ACA/DCA¸¸)
Àú¼ÒºñÀü·Âȸ·Î·Î ÀüÁö Àý¾à
 
 
 
  When load current is not affected by the distortion, both averaging value type and true RMS (root mean square) type clamp meters show the almost same value of about 10A with constant wave-form as the above display samples. However, when load current is affected by some distortions such as inverter, etc...,averaging value type clamp meter indicates 5.5A instead of 9.7A and true RMS type clamp meter indicates 7.9A instead of 9.7A with irregular wave-form. Accordingly, true RMS type clamp meter is recommendable for the measurement of the equipment with inverter control devices.
Due to the use of thyristors, inverters and other energy-saving controllers in recent electric wiring, current waveforms often include harmonic components and are distorted compared to sinusoidal waves (50/60Hz).
The Kyoritsu True RMS value tester is able to measure distorted waveforms using true RMS since waveforms are being internally calculated continuously. In contrast, when measurements are made with a averaging value tester, errors are generated in the measurement value because the tester cannot continuously track distorted waveforms.

(Compared to the true RMS value tester, measurement values for the averaging value generate more than 30% errors in some cases.)
 
     
 
Range Measuring Range Accuracy
Current Measurement AC A 0 to 100.0A
DC A 0 to ¡¾100.0A
|¡¾2.0%rdg¡¾5dgt (50/60Hz)
|¡¾2.0%rdg¡¾5dgt
Conductor Size Max ¨ª10mm
Non Contact Voltage Detect AC voltage
without contacting
with socket wire
During voltage detection,
"Hi" flashes and
a buzzer sounds intermittently
Dimensions 161.3(L) ¡¿ 40.2(W) ¡¿ 30.3(D)mm
Crest Factor 2.5
Weight 110g (with batteries)
Maximum Digit 1,049
Safety Standard IEC 61010-1 CAT.III 300V Pollution Degree 2
Power Source R03 (AAA) ¡¿ 2
Accessories Carrying Case
R03 (AAA) ¡¿ 2
Instruction Manual
1 Àü¾Ð°¨Áö±â´É(NCV:Non Contact Voltage)
Àü¼±, Àü±Øµî¿¡ Á¢ÃËÇÏÁö ¾Ê°í Àü¾ÐÀÇ À¯¹«¸¦ È®ÀÎÇÏ´Â ±â´ÉÀÔ´Ï´Ù. (ÄÉÀ̺í. Äܼ¾Æ®.ÈÞÁî. ȸ·ÎÂ÷´Ü±â. ¹èÀü¹Ýµî¿¡¼­ ¾ÈÀüÇÏ°Ô ACÀü¾ÐÀÇ Á¸À縦 °£´ÜÈ÷ È®ÀÎÇÒ¼ö ÀÖ½À´Ï´Ù.)

2 CF(ÆÄ°íÀ²)
ÆÄ°íÄ¡¿Í ½ÇÈ¿Ä¡¸¦ ºñ±³Çϴµ¥ ÀÖ¾î ´ÙÀ̳ª¹Í·»ÁöÀÇ ³ÐÀ̸¦ ³ªÅ¸³À´Ï´Ù. ÆÄ°íÀ²Àº ÆÄÇü ¿Ö°î¾øÀÌ Á¤ÇöÆķμ­ 1.41ÀÔ´Ï´Ù. ÀÌ °ª¿¡¼­ ¹þ¾î³ª¸é ÆÄÇüÀÌ ¿Ö°îµÇ¾ú´Ù´Â ÀǹÌÀÔ´Ï´Ù
±¸¸Å¾È³»

- º» »óÇ°Àº °³ÀÎÀÇ ¸ð´ÏÅÍ »ç¾ç¿¡ µû¶ó µðÀÚÀÎ/»ö»óÀÌ ´Ù¼Ò Â÷ÀÌ°¡ ÀÖÀ» ¼ö ÀÖ½À´Ï´Ù.
- Åë½ÅÆǸž÷½Å°í¹øÈ£  Á¦ 2010 - ¼­¿ï±¸·Î - 1064 È£
- ÀԱݰèÁ : ½ÅÇÑÀºÇà 364-04-813036 (¿¹±ÝÁÖ : Á¶¿µ¼ö)
- ±Ã±ÝÇϽŠ»çÇ×À̳ª ÀÚ¼¼ÇÑ ³»¿ëÀº 02)6679-8243~6 ·Î ¹®ÀÇ ÁÖ½Ã¸é »ó¼¼È÷ ´äº¯µå¸®°Ú½À´Ï´Ù.

Copyright(C) 2007 WOOJINTESTER All rights reserved
ÁÖ¼Ò : ¼­¿ï ±¸·Î±¸ ±¸·Îº»µ¿ Áß¾ÓÀ¯Åë´ÜÁö ¹Ùµ¿1314È£  ¿ìÁøÅ×Å©   ´ëÇ¥: Á¶¿µ¼ö
»ç¾÷ÀÚµî·Ï¹øÈ£: 113-17-29368   Åë½ÅÆǸÅ: Á¦ 2010-¼­¿ï±¸·Î-1064È£   E-Mail:
Tel: 02)6679-8243~6   Fax: 02)6679-6097