Fluke 287, 289 True-rms Logging Multimeter
¡° 50,000 count, 0.025% accuracy, TrendCapture, logging, PC connetion ¡±
• ¹é»ö ¹é¶óÀÌÆ®ÀÇ 50,000 Ä«¿îÆ®, 1/4 VGA Å« µð½ºÇ÷¹ÀÌ È¸é
• µ¥ÀÌÅͷαë, Æ®·»µåĸÃÄ: ¼³°è¿Í °øÁ¤ ¼º´É ÃøÁ¤À̳ª ºÎÀç½Ã ½Ã½ºÅÛ ¸ð´ÏÅ͸µÀ» À§ÇÑ ÃÖÀûÀÇ ±â´ÉÀÔ´Ï´Ù. 200½Ã°£ ¿¬¼ÓÀ¸·Î 10,000°³ÀÇ ÃøÁ¤°ªÀ» ÀúÀåÇÒ ¼ö ÀÖÀ¸¸ç, Æ®·»µåĸÃÄ ±â´ÉÀ¸·Î PC¾øÀÌ ·Î±ëµÈ °ªÀÇ ÃßÀ̸¦ ±×·¡ÇÁ·Î È®ÀÎÇÒ ¼ö ÀÖ½À´Ï´Ù.
• ¡° i ¡± ¹öÆ°: ÃøÁ¤±â´É¿¡ ´ëÇÑ Á¤º¸¸¦ º¼ ¼ö ÀÖ½À´Ï´Ù.
• LoZ ±â´É: °í½ºÆ®Àü¾Ð¿¡ ÀÇÇÑ À߸øµÈ ÃøÁ¤À» ¹æÁö (289 only)
• LPF(Low Pass Filter) ±â´É: ¸ðÅ͵å¶óÀÌºê ½ÅÈ£¿Í °°Àº ³ëÀÌÁî°¡ ¸¹Àº ½ÅÈ£¸¦ Á¤È®ÇÏ°Ô ÃøÁ¤ (289 only)
• Low ohm ÃøÁ¤: 10mA Àü·ù·Î 50¿È ÃøÁ¤¹üÀ§, 1¹Ð¸®¿È ºÐÇØ´É ÃøÁ¤ (289 only)
• ÃøÁ¤°ª ÀúÀå±â´É: ÀúÀåµÈ ÃøÁ¤°ªÀÇ À̸§º¯°æÀÌ °¡´ÉÇϸç, ÇöÀå¿¡¼ ÀúÀå°ªÀ» È®ÀÎÇÒ ¼ö ÀÖ½À´Ï´Ù.
• ½Ç½Ã°£ ½Ã°è: ÃøÁ¤°ª¿¡ ÀÚµ¿À¸·Î ÃøÁ¤½Ã°£À» Ç¥½ÃÇÕ´Ï´Ù.
• Àåºñ ¾÷µ¥ÀÌÆ®: Àåºñ ±â´ÉÀÌ Ãß°¡µÇ¸é, ÄÉÀ̺í°ú ¾÷µ¥ÀÌÆ® ÆÄÀÏ·Î ±â´ÉÀ» Ãß°¡ÇÒ ¼ö ÀÖ½À´Ï´Ù.
• 0.025%, DCÁ¤È®µµ
• 100kHz, AC ÁÖÆļö´ë¿ª
• True-rms ÃøÁ¤¹æ½Ä (ºñ¼±ÇüºÎÇÏÀÇ Á¤È®ÇÑ ÃøÁ¤)
• 100mF ijÆнÃÅϽº ÃøÁ¤¹üÀ§
• ¿ÂµµÃøÁ¤
• Relative Mode: Å×½ºÆ®¸®µå¿¡ ÀÇÇÑ ÀúÇ×¼ººÐ Á¦°Å
• Fast Min/Max: 250us °úµµ½ÅÈ£ÀÇ ÇÇÅ©°ª °ËÃâ
• PCÅë½Å: ±¤ÄÉÀ̺í°ú FVF ¼ÒÇÁÆ®¿þ¾î·Î ·Î±ë ¹× ÀúÀåµÈ µ¥ÀÌÅ͸¦ ÄÄÇ»ÅÍ·Î Àü¼Û
• FVF (FlukeView Forms): °¢ ÃøÁ¤°ªÀ» ÀúÀå, ºÐ¼® ¹®¼È°¡ °¡´ÉÇÑ ¼ÒÇÁÆ®¿þ¾î
• º¸Áõ±â°£ Æò»ý
• CAT III 1000V / CAT IV 600V
¡Ø Á¦Ç°±¸¼º ¹× ÄÞº¸Å°Æ®
|
Fluke 287, 289±âº»±¸¼ºÇ°
• 289 or 287 ¸ÖƼ¹ÌÅÍ
• TL71 Å×½ºÆ®¸®µå
• AC72 ¾Ç¾îŬ¸³
• ¸Þ´º¾ó CD |
|
289/FVF ¼ÒÇÁÆ®¿þ¾î ÄÞº¸Å°Æ®
• 289 ¸ÖƼ¹ÌÅÍ
• C280 ¼ÒÇÁÆ®ÄÉÀ̽º
• TPAK (magnetic hanger)
• TL71 Å×½ºÆ®¸®µå
• AC72 ¾Ç¾îŬ¸³
• 80BK-A ¿ÂµµÇÁ·çºê
• FlukeView Forms Software¿Í ÄÉÀ̺í |
|
287/FVF ¼ÒÇÁÆ®¿þ¾î ÄÞº¸Å°Æ®
• 287 ¸ÖƼ¹ÌÅÍ
• C280 ¼ÒÇÁÆ®ÄÉÀ̽º
• ¸ðµâÇü Å×½ºÆ®¸®µå,ÇÁ·çºê,¾Ç¾îŬ¸³
• 80BK-A ¿ÂµµÇÁ·çºê
• FlukeView Forms Software¿Í ÄÉÀ̺í |
|
TLK289 Å×½ºÆ®¸®µå ¼¼Æ®(289)
• TL224 Å×½ºÆ®¸®µå ¼¼Æ®
• TPAK (Magnetic hanger)
• 80BK-A ¿ÂµµÇÁ·çºê
• C116 ¼ÒÇÁÆ®ÄÉÀ̽º |
|
TLK287 Å×½ºÆ®¸®µå ¼¼Æ®(287)
• TL910 ÀüÀÚ¿ë Á¤¹ÐÇÁ·çºê
• Micro-grabbers, leads
• Mini ¾Ç¾îŬ¸³, grabber, ÇÁ·çºê |
|
Fluke-289/IMSK Combo Kit
• Fluke-289 DMM
• i400 AC 400A Current Clamp
• TL71 Test Leads • AC72 Alligator Clips |
¡Ø »ó¼¼»ç¾ç
Specification |
Voltage DC |
Accuracy |
0.025 % |
Range and Resolution |
50.000 mV,500.00 mV, 5.0000 V,
50.000 V, 500.00 V, 1000.0V |
|
Voltage AC |
Accuracy |
0.4 %(true-rms) |
Range and Resolution |
50.000 mV,500.00 mV, 5.0000 V,
50.000 V, 500.00 V, 1000.0V |
|
Current DC |
Accuracy |
0.06 % |
Range and Resolution |
500.00 µA, 5000.0 µA,
50.000 mA, 400.00 mA,
5.0000 A, 10.000 A |
|
Current AC |
Accuracy |
0.61 %(true-rms) |
Range and Resolution |
500.00 µA, 5000.0 µA,
50.000 mA, 400.00 mA,
5.0000 A, 10.000 A |
|
Temperature (excluding probe) |
Accuracy |
1.0 % |
Range and Resolution |
-200.0 ¡ÆC to 1350.0 ¡ÆC
(-328.0 ¡ÆF to 2462.0 ¡ÆF) |
|
Resistance |
Accuracy |
0.05 % |
Range and Resolution |
500.00 §Ù, 5.0000 k§Ù, 50.000 k§Ù,
500.00 k§Ù, 5.0000 M§Ù,
50.00 M§Ù, 500.0 M§Ù |
|
Resistance 10 50 §Ù (2 wire connection) |
Accuracy |
0.15 % + 20 |
Range and resolution |
50.000 §Ù |
|
Capacitance |
Accuracy |
1.0 % |
Range and Resolution |
1.000 nF,10.00 nF 100.0 nF,
1.000 µF, 10.00 µF, 100.0 µF,
1000 µF, 10.00 mF, 100.00 mF §Ù |
|
Frequency |
Accuracy |
0.005% + 5 |
Range and Resolution |
99.999 Hz, 999.99 Hz,
9.9999 kHz, 99.999 kHz,
999.99 kHz |
|
Additional functions/features |
Multiple on-screen |
Yes |
True-rms AC band |
100 kHz |
DBV/dBm |
Yes |
DC mV resolution |
1 ¥ìV |
Megohm range |
Up to 500 M |
Conductance |
50.00nS |
Continuity beeper |
Yes |
Battery/Fuse access |
Battery / Fuse |
Peak |
250 ¥ìS |
Elapse time clock |
Yes |
Time of day clock |
Yes |
Min-Max-Avg |
Yes |
Frequency |
Yes |
Duty Cycle |
0.01 % to 99.99 % |
Pulse Width |
0.025 ms, 0.25 ms, 2.5 ms, 1250.0 ms |
Hold |
Yes |
Optical connection |
Yes |
Auto/Touch Hold |
Yes |
Reading memory |
Yes |
Log to PC |
Yes |
Interval/Event Logging |
Yes |
Logging Memory |
Up to 10,000 readings |
Resistance Low Ohm |
0.001 ¥Ø to 50.000 ¥Ø
10 mA source (289 only) |
LoZ |
Yes (289 only) |
Low Pass Filter |
Yes |
| |