¡Ø ±âº»»ç¾ç
- ÃøÁ¤±â´É : °Ë»ó(Á¤»ó, ¿ª»ó), È°¼±Ã¼Å©
- µ¿ÀÛÀü¾Ð : ¹üÀ§ AC70~600V, 50/60 Hz(Á¤ÇöÆÄ, ¿¬¼Ó ÀÔ·Â), Á¤Àü À¯µµ½Ä °ËÃâ
- Á¢¼Ó°¡´É : µµÃ¼Áö¸§ ¸¶¹«¸® ¿Ü°æ¥õ17 mm(µµÃ¼ ´Ü¸éÀû 100 mm2»ó´ç)±îÁöÀÇ Àý¿¬ Àü¼±
- Ç¥½Ã [Á¤»ó]°Ë»ó·¥ÇÁ 4µîÀÌ ½Ã°èȸÀü¿¡ Â÷·ÊÂ÷·Ê Á¡µî£¦´Ü¼ÓÀ½ [¿ª»ó]°Ë»ó·¥ÇÁ 4µîÀÌ ¹Ý½Ã°èȸÀü¿¡ Â÷·ÊÂ÷·Ê Á¡µî£¦¿¬¼ÓÀ½ [È°Àü]µ¿ÀÛ Àü¾Ð ¹üÀ§³»¿¡¼ R-S, S-T·¥ÇÁ Á¡µî
- ÀüÁöüũ : Àü¿ø ON½Ã£ºON·¥ÇÁ Á¡µî, ÀüÁö ¼Ò¸ð½Ã£ºON·¥ÇÁ Á¡¸ê ¿ÀÅä ÆÄ¿ö ¿ÀÇÁ Àü¿ø ÅõÀÔ ÈÄ, ¾à 15ºÐ °æ°úÈÄ¿¡ Àü¿ø OFF
- Àü ¿ø : ´Ü 3Çü ¸Á°£ °ÇÀüÁö(R6P) ¡¿ 2, ¿¬¼Ó »ç¿ë½Ã°£: 70 h
- Ä¡¼ö¡¤Áú·® : 70W ¡¿ 75H ¡¿ 30Dmm, 200g, ÄÉÀ̺íÀå: 0.7 m ºÎ¼ÓÇ° ÈÞ´ë¿ë ÄÉÀ̽º¡¿ 1, ½ºÆ®·¦¡¿ 1, ´Ü 3Çü ¸Á°£ °ÇÀüÁö
[ Æí ¸® ÇÑ Á¡ ]
- °Ë»ó±â Åé Ŭ·¡½ºÀÇ ¾ÈÀü¼º ¡¡ CE¸¶Å· ´ëÀÀ, CAT III 600 VÀÇ °Ë»ó±â Åé Ŭ·¡½ºÀÇ ¾ÈÀü ¼³°è
- ÇǺ¹ Àü¼± À§·ÎºÎÅÍ °Ë»óÀ» ½ÇÇö ¡¡ Á¤Àü À¯µµ½Ä Àü¾Ð ¼¾¼(ºñÁ¢Ã˽Ä)ÀÇ Ã¤¿ë¿¡ ÀÇÇØ, ÇǺ¹ Àü¼± À§·ÎºÎÅÍ °£´ÜÇÏ°Ô ÃøÁ¤ÇÒ ¼ö ÀÖ½À´Ï´Ù.
- ÃøÁ¤ ºóµµ°¡ ³ôÀº Àü¼± ¿Ü°æÀ» ¼Õ½±°Ô ÃøÁ¤ ¡¡ Àü¼± ¿Ü°æ¥õ17 mm(100 mm2»ó´ç Àü¼±)±îÁö Á¢¼ÓÇÒ ¼ö ÀÖ½À´Ï´Ù.
- °Ë»óÀ» ºû°ú ¼Ò¸®·Î ¼Æ÷Æ® ¡¡ »ó¼øÀ» 4µî LED Ç¥½Ã·Î ȸÀü ¹æÇâÀ» Ç¥½Ã, ¾îµÎ¿î ÇöÀå¿¡¼µµ ¿ëÀÌÇÏ°Ô ÆÇÁ¤ÇÒ ¼ö ÀÖ½À´Ï´Ù.°Ô´Ù°¡ 2 Á¾·ùÀÇ ¹öÀúÀ½À¸·Î Á¤»ó/¿ª»óÀÇ ÆÇÁ¤À» ¼Æ÷Æ®ÇÕ´Ï´Ù.
- °£ÀÌ°ËÀü, Àü¼±ÀÇ È°¼±Ã¼Å© ±â´É ¡¡ Àü¼±ÀÇ È°¼±»óŸ¦ ¾Ë ¼ö ÀÖ´Â ¼±°£ Ç¥½Ã¿¡ °¡¼¼ÇØ °£ÀÌ°ËÀüÀ¸·Î¼ »ç¿ëÇÒ ¼ö ÀÖ½À´Ï´Ù.
- Àü¿øÀÇ ÀÚ¸£´Â °ÍÀ» Àؾ ¹æÁöÇÏ´Â, ¿ÀÅä ÆÄ¿ö ¿ÀÇÁ ±â´ÉÀ» žÀç.
- ÀüÁöÀÇ ¼Ò¸ð »óŸ¦ Àü¿ø ·¥ÇÁ(LED Ç¥½Ã) Á¡¸ê·Î ¾Ë¸®´Â ¾È½É ±â´ÉÀ» žÀç.
- öÀúÇÑ ÄÚ½ºÆ® ¼³°è·Î ±âÁ¸ Á¦Ç° °¡°ÝÀ» Å«ÆøÀ¸·Î ´Ù¿î, Àú°¡°ÝÀ» ½ÇÇö.
[ ÁÖ »ç ¿ë ó ]
- Àü±â°ø»ç¾÷, ¼³ºñ ¸àÅ׳ͽº, ºôµù/°øÀåµîÀÇ º¸¼ö/Á¡°Ëµî¿¡ »ç¿ëÇÒ ¼ö ÀÖ½À´Ï´Ù.
Measurement Function |
Phase detection (positive,negative),live wire check (R-S/S-T only) |
Voltage Detection Method |
Electrostatic induction method |
Voltage Range |
70 to 1000VAC (50/60Hz)(sine wave,continuous input) |
Clamp Diameter |
10 to 40mm of insulated wiring |
Display |
Phase Detection : |
Positive ; |
4 LEDs lit in clockwise order and 3 short beeps |
|
Negative ; |
4 LEDs lit in counterclockwise order and one continuous beep |
Live Wire Check : |
R-S and S-T lamps will light if voltage between wires are within voltage range | |
Battery Check Function |
ON lamp blinks to indicate battery low status when instrument is turned on |
Auto Power Off |
Auto shut off if no activity is detected after power is turned ON for 15 minutes |
Power supply |
Two AA size batteries ¡¿ 2 (rated voltage:DC3.0V; maximum rated ower:300mVA) |
Continuous Use |
approx.70 hours (standby) |
Dimensions, mass |
70 mm (2.76 in)W x 75 mm (2.95 in)H x 30 mm (1.18 in)D, 240g (8.5 oz), Cord length : 0.7m(27.56 in) |
Accessories |
Carrying case(1), strap(1), R6P manganese batteries(2), spiral tube(1) | | |