¾Æ´äÅʹ Ŭ·¥ÇÁ ¹ÌÅÍÀÇ ÃøÁ¤ ´É·ÂÀÓÀ» Çâ»ó½ÃÅ°µµ·Ï ¼³°èÇÑ °ÍÀÌ´Ù. MULTI- TRAN À» »ç¿ëÇÒ °æ¿ì ÃøÁ¤ ¹üÀ§¸¦ ´Ã¸± ¼ö ÀÖÀ» »Ó ¾Æ´Ï¶ó ´õ Å« Á÷°æÀÇ Àü¼±À» °íÁ¤ÇÒ ¼ö ÀÖ´Ù .
|
 |
|
|
 |
Clamp your instrument around the pick-up coil of the multitran. Then, clamp the transformer jaws of the multi-tran on the conductor, as shown below. Multiply the reading of your clamp meter by 10 to obtain the current value measured. | |
|
|
|
|
|
Measuring Range |
0~3000A AC |
Ratio/Range |
10 : 1 (input to output) |
Accuracy |
|¡¾2% of input¡¾0.5A |
Allowable Measurement Time |
0~1000A (continuous), 1000~1500A (10 minutes max.) 3000A (30 seconds max.) |
Conductor Size |
¨ª100mm max.(100 ¡¿ 150mm) |
Frequency Response |
50Hz/60Hz |
Safety Standard |
IEC61010-1 CAT.III 300V Pollution Degree 2 |
Withstand Voltage |
3000V AC for 1 minute |
Dimensions |
317(L) ¡¿ 150(W) ¡¿ 30(D)mm 45(L) ¡¿ 40(W) ¡¿ 10(D)mm Output coil |
Weight |
750g approx. |
Accessories |
9056(Carrying Case) |
For use with following models * |
2002PA, 2002R, 2003A(AC only), 2004(AC only), 2006, 2007A(AC only), 2009A(AC only), 2608A, 2805, 2017, 2027, 2037(AC only), 2412, 2417, 8113(AC only), 2031, 2033(AC only), 2431, 2432, 2433, 2433R, 2434 | |
|